Home » UNIQUE Fire Stop Products Store » Membrane Firestop Sleeve

Membrane Firestop Sleeve

$49.00$69.00

Close
Price Summary
  • $69.00
  • $49.00
  • $49.00
In Stock
Highlights:

When the job calls for a cable outlet inside a firewall or smoke wall, our Membrane Firestop Cable Sleeve is uniquely qualified for the job. UNIQUE’s angled design permits a BUNDLE of cables to be dropped inside the Firewall membrane, making it the ONLY mechanical multi-cable system available that maintains proper bend radius specs.

Clear
Description

Description

When you need to install a cable outlet inside a firewall or smoke wall, our Membrane Firestop Cable Sleeve is uniquely qualified for the job. Our “angled design” allows a BUNDLE of cables to be dropped inside a Firewall Membrane. This is the ONLY mechanical multi-cable system available that performs like this while maintaining proper bend radius specs.

This UNIQUE product is an angled firestop cable sleeve that cuts its own hole and installs in 2 minutes, allowing for a UL Classified path to fish cables inside a firewall. The System creates its own hole with the sharp point on the back side of the sleeve. A bead of caulk (not included) is applied to the back of the system and the sleeve is secured to the wall with expanding anchors. UNIQUE Intumescent Putty for sealing this firestopping system is included.

We make this system in the USA in our own factory. UL classified for fire-rated gypsum board/stud walls (one side) for up to 2 hours.

Available in 1″ and 2″ diameters.

System Contents:
Product includes everything you need, including intumescent putty.

  • 1 – Membrane Firestop Cable Sleeve, a 6″ square metal plate with a 1″ or 2″ inch sleeve (6″ long) welded at a 45 degree angle to the plate.
  • 1 – plastic bushing
  • 2 – expanding wall anchors (for use in 5/8 thick fire-rated drywall)
  • 1 – UNIQUE Intumescent Putty
  • 1 – documentation/warning label

Guaranteed AHJ acceptance. Your System is approved when the Inspector says it is! Now we offer two ways to submit your request form to the AHJ:

  1. Download the original AHJ Request Form for pre-approval of your firestopping system. Use it for submission to the Inspector so he/she may pre-approve your proposed System.
  2. Use our convenient new form to email your proposed firestopping system specs to your AHJ- (Authority Having Jurisdiction)- for preapproval. See the new form on the ‘Inspector Form’ tab.

See also Unique Firestop Caulk – You will apply a small bead of firestop caulk to the back of the plate and around the sleeve to seal the Membrane Firestop to the wall.

See also our 1″ Membrane Firestop System Kit— Contains one each of the following items, all in one kit:

  • 1″ Membrane Firestop Cable Sleeve- everything above including UNIQUE Intumescent Putty
  • Retrofit Metal Box- single
  • Retrofit Box Pad- single
  • Retrofit Plate Guard- single

All UNIQUE firestop cable sleeve systems include enough UNIQUE Intumescent Putty for a minimum 25% and maximum of 48% cable load. Order an additional Intumescent Putty Fill Kit here if needed.

Take our Free Training and Certification Test to become one of our Certified Installers and receive special discounted pricing on our products.

Additional information

Additional information

Weight N/A
Dimensions N/A
Sizes

1 inch, 2 inch

Installation Pictorial

Installation Pictorial

mp1in-contents(100sq) System contents: Membrane Firestop Cable Sleeve, bushing, anchors, label and UNIQUE Intumescent Putty.
mp-install2 Prior to installation, remove the anchors, putty, label, and plastic bushing.
mp-install3 Determine the cable wall outlet’s location and place the pointed leading edge of the sleeve plate directly above your cable outlet (above the grid). Carefully drive the Membrane Firestop Cable Sleeve into the wall.
mp-install4 Make sure the plate fits flush against the wall. Now, remove the plate and go on to the next step.
Be sure to clean out the back of the wall where the hole was made by the sleeve.
mp-install5(100sq) Apply a small bead of firestop caulk to the back of the plate and around the sleeve to seal the Membrane Firestop to the wall. Re-insert the system into the hole you made.
mp-install6 Now, carefully drive the expanding anchors through the face of the system and in the drywall.
mp-install7 There are small slots in the holes for the anchor to grab, allowing you to fully expand the anchor while securing the plate flush to the wall. Note: The Membrane Firestop is now permanently installed. Don’t forget to carefully push the bushing back on. Drop your cables through the sleeve and down to the wall outlet.
mp-install8 Cable load is 40%. Apply an inch thickness of the supplied intumescent putty in the top of the sleeve. Be sure to fill out the Documentation Warning Label. It is recommended that you take a picture of your installed System for future reference.
Inspector Form

Inspector Form

Use this convenient form to send your proposed firestopping system specs to your AHJ- (Authority Having Jurisdiction)- for preapproval. Your System is approved when the Inspector says it is! Note that you will use one AHJ form for each UNIQUE firestop product you specify.

You may also need…

Scroll To Top
  • Menu
  • Categories
Close
Close

My Cart

Shopping cart is empty!

Continue Shopping